Cleaning & Maintenance

Proper maintenance ensures reliable performance and extends the life of your Data Walker.

Cleaning the Device

Main Unit

  • Wipe the enclosure with a soft, damp cloth
  • Use isopropyl alcohol (70%) for disinfection
  • Avoid getting moisture in the USB port
  • Do not use abrasive cleaners or solvents
  • Allow to dry completely before use

Display

  • Clean with a microfiber cloth
  • Use screen cleaner if needed (spray on cloth, not screen)
  • Do not press hard on the display

Sensor and Cable

  • Wipe sensor housing with alcohol wipes
  • Check RJ22 connectors for debris
  • Inspect cable for wear or damage
  • Replace cable if outer sheath is damaged

Wheel Magnets

  • Periodically check that magnets are secure
  • Clean adhesive residue if a magnet comes loose
  • Re-attach with strong adhesive (cyanoacrylate or epoxy)
  • Run self-test after replacing any magnet

Inspection Schedule

Recommended inspection frequency:

  • Daily: Visual check of display and connections
  • Weekly: Clean enclosure, check cable condition
  • Monthly: Run self-test, verify calibration, check magnets
  • Quarterly: Full calibration verification against measured course

Storage

  • Store in a dry location
  • Avoid extreme temperatures (below 0°C or above 45°C)
  • Keep away from strong magnetic fields
  • Charge battery before long-term storage
  • Coil cables loosely to prevent damage